2024-04-21
A Comparative Study on Pork Quality and Shelf Life Based on Packaging Types
X = number of micro-organisms (CFU/g)
A = number of CFU counted on the plate
V = reciproque value of the corresponding dilution
I = volume of inoculum (1 mL for pour plates, 0.1 mL for spread plates)
Day 7: For the total aerobic psychrotrophic count, with a best before date of 3 x 106 cfu/g, the concentration was unsatisfied across all types of packaging including original, MAP, and vacuum. However, in the case of lactic acid bacteria (best before date = 3 x 107 cfu/g), the concentration was acceptable in all packaging types. Similarly, for yeast (best before date = 3 x 105 cfu/g), the concentration was also acceptable in all packaging types. As for molds (best before date = no visible mold formation), no molds were observed in any of the packaging types, indicating that they were acceptable.
To sum up, the experimental results showed that vacuum packaging, MAP, and original packaging are beneficial in that order in terms of preventing spoilage.